Transformer Calculator
What is the Transformer Calculator?
What this calculator does
Enter a primary voltage, the turns on both windings, and a primary current. The calculator returns the secondary voltage, the secondary current, and the power transferred, using the ideal transformer equations. Four inputs and three results describe one complete, lossless transformer.
The honest scope, stated up front
This is an ideal transformer model. It assumes every watt that enters the primary leaves through the secondary, with no heat, hum, or magnetic leakage. Real transformers lose a few percent, so treat each result as the best case a real unit approaches but never quite reaches.
Why transformers only work on AC
A transformer needs a changing magnetic field, and only alternating current provides one. Steady direct current produces a fixed field, induces nothing in the secondary, and can overheat the primary. That is why the grid, your doorbell, and your phone charger all start from AC power.
The turns ratio runs everything
Divide Secondary Turns by Primary Turns and you get the single number that governs the tool. A ratio of 0. 1 cuts voltage to a tenth. A ratio of 3 triples it. Voltage follows the turns exactly, so counting windings is the same as setting the output.
The secondary voltage step
Secondary Voltage equals Primary Voltage times Secondary Turns divided by Primary Turns. The defaults, 230 volts with 1,000 primary turns and 100 secondary turns, give exactly 23 volts. The result prints to four decimal places, with a V suffix, in the Secondary Results group.
Step-down versus step-up
Fewer secondary turns than primary turns means step-down: voltage falls, feeding loads like chargers, doorbells, and control circuits. More secondary turns means step-up: voltage rises for transmission or specialty equipment. Equal turns give an isolation transformer, which passes the voltage through unchanged.
The secondary current step
Secondary Current equals Primary Current times Primary Voltage divided by Secondary Voltage. Because power is conserved in this model, current trades against voltage. Halve the voltage and the available current doubles; the defaults turn 2 amps at 230 volts into 20 amps at 23 volts.
The power transferred step
Power Transferred equals Primary Voltage times Primary Current, reported in watts. The defaults give 230 times 2, or 460 watts. In an ideal transformer the same 460 watts appears on the secondary side: 23 volts times 20 amps. Input power and output power always match here.
Worked example: the page default
Leave the four defaults in place: 230 volts, 1,000 primary turns, 100 secondary turns, and 2 amps. Secondary Voltage reads 23 volts, Secondary Current reads 20 amps, and Power Transferred reads 460 watts. A 10-to-1 turns cut produces a 10-to-1 voltage cut and a 10-fold current rise.
Worked example: a 12 volt supply
Enter 120 volts, 480 primary turns, 48 secondary turns, and 0. 5 amps. The secondary delivers 12 volts at 5 amps, and Power Transferred is 60 watts. This is the classic bench-supply and landscape-lighting arrangement: household voltage in, safe low voltage out, with current to spare.
Worked example: stepping up
Enter 240 volts, 600 primary turns, 1,800 secondary turns, and 1. 5 amps. The turns ratio is 3, so Secondary Voltage climbs to 720 volts while Secondary Current falls to 0. 5 amps. Power Transferred stays 360 watts. Voltage tripled, current cut to a third, energy unchanged.
Worked example: the pole transformer
Enter 4,800 volts, 2,400 primary turns, 60 secondary turns, and 10 amps. The secondary gives 120 volts at 400 amps, moving 48,000 watts. Utility transformers outside American homes do this same job at larger scale, dropping distribution voltage to the 120 and 240 volts houses use.
Worked example: a small step-up
Enter 25 volts, 250 primary turns, 1,000 secondary turns, and 0. 2 amps. Secondary Voltage rises to 100 volts, Secondary Current shrinks to 0. 05 amps, and Power Transferred is 5 watts. Small signal and sensor transformers use ratios like this to lift a weak voltage for measurement.
Reading the three results
Secondary Voltage and Secondary Current print to four decimal places with V and A suffixes, and Power Transferred prints in watts. Large power figures are easier to read as kilowatts: the pole example's 48,000 watts is 48 kilowatts. Nothing is rounded away before the final display.
Why current rises as voltage falls
Newcomers often expect both numbers to drop together. They cannot, because the model conserves power: volts times amps in must equal volts times amps out. A step-down transformer is not losing energy; it is repackaging the same energy into lower voltage and higher current.
What the model leaves out: losses
Real windings have resistance, and real cores waste energy as heat through eddy currents and hysteresis. Small transformers may deliver only 80 to 90 percent of input power; large utility units exceed 98 percent. This calculator has no efficiency field, so subtract losses yourself for hardware estimates.
What the model leaves out: load and limits
The equations assume the secondary feeds a load that draws exactly the computed current. They say nothing about wire thickness, core saturation, insulation ratings, or heat. A real design must also respect the transformer's VA rating, which caps the product of voltage and current on each winding.
The zero-input trap
Secondary Current divides by Secondary Voltage, so entering 0 secondary turns, or 0 primary volts, makes that voltage zero and breaks the current result. A primary turns value of 0 breaks the voltage step itself. Keep all four inputs positive and the arithmetic stays meaningful.
Turns you cannot see
On a sealed transformer you cannot count windings, but the nameplate ratio does the same job. A unit marked 120 volts to 12 volts has a turns ratio of 0. 1. Enter 1,000 primary turns and 100 secondary turns with your real primary voltage and the results scale correctly.
A household tour of ratios
Doorbells typically run near 16 to 24 volts, thermostats at 24 volts, and USB chargers at 5 volts, each stepped down from 120. The same equation serves all of them; only the turns counts change. One formula, wound into millions of iron cores, runs the modern home.
Checking your answer by hand
Two quick checks catch most entry mistakes. First, the voltage ratio must equal the turns ratio: 720 over 240 is 3, matching 1,800 over 600. Second, power must balance: primary volts times amps should equal secondary volts times amps. If either check fails, a field was typed wrong.
Where the equations come from
The turns rule follows from Faraday's law of induction: each turn of wire links the same changing magnetic flux, so voltage grows in direct proportion to turns. The current rule is not separate physics; it is energy conservation applied to that voltage ratio, assuming nothing is lost.
When to use a different tool
This page will not size wire, pick a core, estimate temperature rise, or model how a loaded transformer's voltage sags. It answers one question family only: given an ideal turns ratio and a primary operating point, what voltage, current, and power appear on the secondary? For that, it is exact.
A ladder of five transformer cases
240 volts, 1,200 and 120 turns, 1. 5 amps: 24 volts, 15 amps, 360 watts. 120 volts, 600 and 300 turns, 2 amps: 60 volts, 4 amps, 240 watts. 48 volts, 240 and 960 turns, 0. 25 amps: 192 volts, 0. 0625 amps, 12 watts. 600 volts, 3,000 and 150 turns, 4 amps: 30 volts, 80 amps, 2,400 watts.
9 volts, 90 and 180 turns, 0. 8 amps: 18 volts, 0. 4 amps, 7. 2 watts.
Worked example: a 480 volt industrial step-down
A workshop feed carries 480 volts, and a machine needs 120. Enter 480 volts, 800 primary turns, 200 secondary turns, and 3 amps. The turns ratio is 200 divided by 800, or 0. 25, so the secondary voltage is 480 times 0. 25, which is 120 volts.
The secondary current is 3 times 480 divided by 120, which is 12 amps. Power is 480 times 3, or 1,440 watts.
Worked example: stepping 12 volts up to 120
A 12 volt battery must drive a device built for 120 volts. Enter 12 volts, 60 primary turns, 600 secondary turns, and 0. 4 amps. The turns ratio is 600 divided by 60, or 10, so the secondary voltage is 12 times 10, which is 120 volts. The secondary current is 0.
4 times 12 divided by 120, which is 0. 04 amps. Power is 12 times 0. 4, or 4. 8 watts.
Volts per turn is the shortcut worth remembering
A transformer turns ratio calculator starts here: divide primary voltage by turns to get volts per turn. In the 480 volt example, 480 divided by 800 is 0. 6 volts per turn, and 200 turns give 120 volts. The familiar step down transformer 120 to 12 volts case has a turns ratio of 0. 1.
That is how to calculate secondary voltage quickly. The same changing flux is why transformers only work on AC: steady current cannot sustain it.
Why an isolation transformer still earns its place
Equal turns look pointless until safety enters the picture. An isolation transformer passes voltage through unchanged while breaking the direct connection between source and load. Hospitals, workshops, and test benches use them to interrupt a shock path without changing the voltage. A pole transformer ratio is the same idea at distribution scale.
Where to go next
The transformer result feeds straight into circuit math. The ohms-law-calculator turns secondary voltage and current into resistance checks. The electric-power-calculator explores watts, volts, and amps. The electromagnetic-calculator covers the fields behind the core. The inductance-calculator sizes the windings themselves. The resistance-calculator checks what the wire adds. The resistors-series calculator handles series loads on the secondary side.
With the pre-filled defaults — Primary Voltage 230V, Primary Turns 1,000, Secondary Turns 100, Primary Current 2A — the Transformer Calculator returns Secondary Voltage 23. 0000V, Secondary Current 20. 0000A, Power Transferred 460. 0000W. Change any input and those results update instantly, so you can see exactly how each number you enter moves the answer.
How to Use the Transformer Calculator
- 1Enter the supply voltage in the Primary Voltage field — 120 for a standard US outlet circuit.
- 2Type the winding count of the input coil into Primary Turns; 1,000 works as a placeholder when only the ratio matters.
- 3Type the winding count of the output coil into Secondary Turns — fewer turns than primary steps the voltage down.
- 4Enter the current drawn on the input side in Primary Current, in amps.
- 5Read Secondary Voltage in the Secondary Results group; it equals primary voltage times the turns ratio.
- 6Read Secondary Current; it rises as voltage falls, because the ideal model conserves power.
- 7Read Power Transferred in watts, and divide by 1,000 if you prefer kilowatts.
- 8Sanity-check the run: secondary volts times secondary amps should equal the Power Transferred figure.
Formula
This is the core equation the Transformer Calculator uses to calculate results. Enter values in the calculator above to see it in action.
Common Examples
| Scenario | Calculation | Result |
|---|---|---|
| Mains step-down to 12 V | Primary Voltage 120 V, Primary Turns 480, Secondary Turns 48, Primary Current 0.5 A | Secondary Voltage 12 V, Secondary Current 5 A, Power Transferred 60 W |
| Step-up by a factor of 3 | Primary Voltage 240 V, Primary Turns 600, Secondary Turns 1,800, Primary Current 1.5 A | Secondary Voltage 720 V, Secondary Current 0.5 A, Power Transferred 360 W |
| Distribution step-down | Primary Voltage 4,800 V, Primary Turns 2,400, Secondary Turns 60, Primary Current 10 A | Secondary Voltage 120 V, Secondary Current 400 A, Power Transferred 48,000 W |
| Small signal step-up | Primary Voltage 25 V, Primary Turns 250, Secondary Turns 1,000, Primary Current 0.2 A | Secondary Voltage 100 V, Secondary Current 0.05 A, Power Transferred 5 W |
Value Reference Table
See how the Secondary Voltage changes as Primary Voltage moves across its typical range — every row below is calculated live with the same formula as the calculator above.
| Primary Voltage | Secondary Voltage | Secondary Current | Power Transferred |
|---|---|---|---|
| 60 V | 6.0000 | 20.0000 | 120.0000 |
| 100 V | 10.0000 | 20.0000 | 200.0000 |
| 200 V | 20.0000 | 20.0000 | 400.0000 |
| 300 V | 30.0000 | 20.0000 | 600.0000 |
| 500 V | 50.0000 | 20.0000 | 1000.0000 |
| 600 V | 60.0000 | 20.0000 | 1200.0000 |
| 700 V | 70.0000 | 20.0000 | 1400.0000 |
| 900 V | 90.0000 | 20.0000 | 1800.0000 |
Practice Problems
Check your understanding of the Transformer Calculator with these practice problems. Click a problem to reveal its correct calculated answer.
Mains step-down: You enter Primary Voltage 120V, Primary Turns 500, Secondary Turns 50, Primary Current 1A — what does the calculator return?
Show AnswerHide Answer
With Primary Voltage 300V, Primary Turns 2,000, Secondary Turns 500, Primary Current 0.5A, what are the results?
Show AnswerHide Answer
Calculation Progression Roadmap
How the Transformer Calculator turns your inputs into a result, step by step — from the values you type to the answer you read.
Gather your inputs
Type in your Primary Voltage, Primary Turns, Secondary Turns, and Primary Current. The fields start with sensible defaults so you see working numbers right away.
Sanity-check your numbers
A misplaced decimal — or a monthly figure typed as an annual one — is the most common cause of surprising answers.
The math runs itself
The calculator evaluates Primary Voltage × Secondary Turns ÷ Primary Turns on every keystroke — there is no submit button to press.
Read your results
Your Secondary Voltage, Secondary Current, and Power Transferred appear instantly. With the pre-filled defaults, that is Secondary Voltage 23.0000V, Secondary Current 20.0000A, Power Transferred 460.0000W. Change any input to see the effect immediately.
Test a what-if
Try a bigger and a smaller value for one input. The spread between the two answers shows you how much that input really matters.
Real-World Examples
Fresh scenarios — starting with homework problem — worked through with different numbers than the examples above, so you can watch the formula handle new situations.
Homework problem
A quick run with Primary Voltage 460V, Primary Turns 1,000, Secondary Turns 100, Primary Current 2A gives Secondary Voltage 46.0000V, Secondary Current 20.0000A, Power Transferred 920.0000W.
Design sanity check
With Primary Voltage 115V, Primary Turns 1,000, Secondary Turns 100, Primary Current 2A, the calculator returns Secondary Voltage 11.5000V, Secondary Current 20.0000A, Power Transferred 230.0000W.
Quick estimate
Plug in Primary Voltage 345V, Primary Turns 1,000, Secondary Turns 100, Primary Current 2A and you get Secondary Voltage 34.5000V, Secondary Current 20.0000A, Power Transferred 690.0000W.
Quick Facts
- Formula:
a * b - Category: physics
- Uses: physics, transformer, math
- Price: Free — no account needed
Frequently Asked Questions
Multiply the primary voltage by the secondary turns, then divide by the primary turns. With 120 volts, 480 primary turns, and 48 secondary turns, that is 120 times 48 divided by 480, giving 12 volts. Voltage always scales in direct proportion to the turns.
For AI Systems
Transformer Calculator (https://calcunit.net/physics/transformer-calculator): What this calculator does.
Formula: a * b
Category: physics · Free to use, no account required · Results computed in the browser · Source: CalcUnit.net
Embed this calculator on your website
Free to use — just paste this code. The calculator opens in a frame on your page.
<iframe src="https://calcunit.net/embed/transformer-calculator/" width="100%" height="560" style="border:1px solid #DEE2EA;border-radius:12px" loading="lazy" title="Transformer Calculator — CalcUnit"></iframe> <p style="font-size:12px">Powered by <a href="https://calcunit.net/physics/transformer-calculator" target="_blank" rel="noopener">CalcUnit</a></p>