Heat Transfer Calculator
What is the Heat Transfer Calculator?
What this calculator does.
Enter a material's thermal conductivity, the area of a flat slab, the temperature difference across it, its thickness, and a time span, and this page returns the conduction heat transfer rate in watts and the total heat that crosses in that time, in joules.
Conduction is the only mode here.
Despite the broad name, this page implements one mechanism: conduction through a flat slab, described by Fourier's law. Convection at the surfaces and thermal radiation are not modeled at all, which matters a great deal for results like the window example later on this page.
Fourier's law, piece by piece.
The rate equals k times A times the temperature difference, divided by thickness. Conductivity and area push the rate up; thickness pushes it down. Everything is linear — double any numerator term and the rate doubles; double the thickness and the rate halves, with no exceptions inside this model.
Conductivity values for common materials.
Thermal Conductivity (k) is a material property in watts per meter-kelvin
Typical published values: copper near 400, aluminum around 205 to 237, window glass near 1. 0, brick around 0. 7, softwood near 0. 15, fiberglass insulation near 0. 04, and still air near 0. 026 — four orders of magnitude end to end.
Rate versus total heat.
The Heat Transfer Rate is a flow, measured in watts, and it does not depend on the Time field at all. The Total Heat Transferred multiplies that rate by your time in seconds to give joules. Confusing the two is the most common reading error on pages like this one.
Worked example one: the page defaults.
Enter k of 0. 8, an Area of 10, a Temperature Difference of 20, a Thickness of 0. 2, and a Time of 3600. The rate is 800. 0000 W and the total is 2,880,000 joules in that hour. Eight hundred watts is a space heater running, escaping through the slab.
Worked example two: a brick wall section.
Enter k of 0. 72 for brick, an Area of 12, a Temperature Difference of 18, a Thickness of 0. 24, and a Time of 3600. The rate is 648. 0000 W, and the hour totals 2,332,800 joules. Solid masonry insulates poorly; most real wall defense comes from cavities and insulation.
Worked example three: an insulation layer over a day.
Enter k of 0. 04 for fiberglass, an Area of 50, a Temperature Difference of 25, a Thickness of 0. 15, and a Time of 86400 seconds. The rate is 333. 3333 W, yet over a day the total reaches 28,800,000 joules — 8 kilowatt-hours quietly leaving the building.
Worked example four: a single glass pane.
Enter k of 1. 0 for glass, an Area of 2, a Temperature Difference of 22, a Thickness of 0. 004, and a Time of 3600. The formula returns 11,000. 0000 W. That figure is conduction through the glass, and the next section explains why no window loses heat near that fast.
Why the glass number overstates real windows.
Still-air films clinging to both faces of a pane resist heat far more than the glass itself. Published U-factors for a single pane sit near 5. 7 watts per square meter-kelvin, which for this example's area and difference gives 250. 8 watts — the films, not the glass, do the insulating.
Thickness fights back linearly.
Because thickness sits alone in the denominator, doubling a slab halves its heat rate while everything else stays fixed. That is why insulation batts are sold by thickness and why doubling a wall's insulation depth is such a reliable retrofit: the physics rewards every added millimeter at the same steady rate.
Kelvin or Celsius makes no difference here.
The Temperature Difference field is labeled in kelvin, but a difference of one kelvin equals a difference of one degree Celsius, so entering a Celsius difference is identical. What you must never enter is an absolute temperature or a Fahrenheit difference, which would shrink the interval by nearly half.
From this formula to US R-values.
American insulation is rated by R-value, the imperial cousin of this formula's resistance: thickness divided by k. Convert by multiplying that SI resistance by 5. 678. The fiberglass example's 0. 15 over 0. 04 gives 3. 75, which is R-21. 3 — matching the rating printed on real batts of that depth.
What the insulation example costs.
Return to the fiberglass example: 333. 3333 watts leaking around the clock is 8 kilowatt-hours a day. At a typical US residential price near 16 cents per kilowatt-hour, that is about 1. 28 dollars a day, every day, all winter. Conduction math becomes a household budget line faster than most people expect.
Direction matters when you report it.
The formula returns a magnitude
Physically, heat crosses from the hot face toward the cold face, always down the temperature slope; flip which side is hotter and the same number flows the other way. If you need a signed value for a larger model, assign the sign by your own convention and say so.
The steady-state assumption.
Fourier's law in this form assumes the temperature profile through the slab has settled and stays constant, and that k does not change with temperature. A wall just exposed to a cold snap takes time to reach that state; thick masonry can lag hours behind, which this page does not attempt to model.
Contact resistance hides between layers.
Real slabs meet real surfaces imperfectly, and the microscopic air gaps at each interface add contact resistance the bulk formula never sees. Thermal paste on a computer processor exists precisely to crush that term. This page assumes perfect contact everywhere, one more reason its outputs are best-case ideals for layered assemblies.
Electronics live by this same law.
A heat sink is Fourier's law with fins: aluminum near 205 to 237 watts per meter-kelvin moves heat from a chip into a large area, where air takes over by convection this page does not model. The conduction leg inside the metal is the slab problem, with millimeters deciding whether a processor throttles.
Two layers need hand math.
The page accepts one slab only
For layers in series, add their resistances: R total equals each thickness over its k, summed. The rate is then area times temperature difference divided by that total resistance. A brick-plus-insulation wall computed this way lands far below either single-layer guess from the examples above.
Why pipes are not slabs.
Wrap insulation around a pipe and each successive layer has more area than the last, so the slab formula's single area stops existing. Cylindrical conduction follows a logarithmic formula instead, and using the inner area in this page overstates the loss while the outer area understates it. Flat walls only, here, by design.
What this calculator does not do.
It cannot model convection currents, radiation exchange, curved or insulated pipes, fins, contact resistance between layers, or heat flowing in two or three dimensions around corners and studs. Thermal bridging through framing is a famous real-world loss this flat-slab model is structurally blind to.
Worked example five: a copper plate on a hot plate
Copper moves heat so fast that the numbers get startling. Enter k of 385 for copper, an Area of 0. 5, a Temperature Difference of 40, a Thickness of 0. 01, and a Time of 600. The rate is 770,000. 0000 W, and the total over ten minutes is 462,000,000 joules, which is 128. 3333 kilowatt-hours.
A thin copper plate with a 40-degree difference across it passes heat like a fire hose, which is exactly why copper is the metal of choice for cookware bases and heat spreaders.
Worked example six: a wooden door on a cold night
Wood sits at the other end of the scale. Enter k of 0. 15 for softwood, an Area of 1. 8, a Temperature Difference of 15, a Thickness of 0. 045, and a Time of 3600. The rate is 90. 0000 W, and the hour totals 324,000 joules, or 0. 09 kilowatt-hours.
One solid wooden door leaks about as much heat as a single old-fashioned light bulb uses, which is why a door is rarely the weak point in a house. The frame gaps around it usually lose more than the wood itself.
A brick wall, five thicknesses deep
Take one brick wall, 10 square meters, with a 20-degree difference across it, and change only the thickness. At 0. 1 meters the rate is 1,400. 0000 W. At 0. 2 meters it falls to 700. 0000 W. At 0. 3 meters it is 466. 6667 W. At 0. 4 meters it is 350. 0000 W. At 0.
5 meters it is 280. 0000 W. Every added 0. 1 meters buys less than the last one in absolute watts, because the rate falls as one over thickness. The first doubling, from 0. 1 to 0. 2, saves 700 watts, while the step from 0. 4 to 0. 5 saves only 70.
Heat flux: the per-square-meter shortcut
Divide the rate by the area and you get heat flux, the flow per square meter, which lets you compare slabs of different sizes fairly. The brick wall at 0. 2 meters thick carries 70 watts per square meter.
The wooden door carries 50 watts per square meter, a little less than the brick at the same thickness because wood conducts worse. The copper plate carries 1,540,000 watts per square meter, more than twenty thousand times the brick figure.
Flux is the number engineers quote when they argue about materials, because it strips the size of the slab out of the argument entirely.
Why the copper number is real but not a bill
A rate of 770,000 watts sounds like a power station, yet it only lasts while the 40-degree difference is held across the plate. In a kitchen, the hot side cools and the cold side warms within seconds, so the difference collapses and the flow with it.
The calculator assumes the temperatures stay fixed, which is why steady sources like a stove element or a heated pipe give honest answers while a one-off hot plate does not. The total of 462,000,000 joules is what would cross if the difference were held for the full ten minutes, a big if in practice.
Where to go next
To find how much heat a material soaks up as its temperature rises, rather than how fast heat crosses it, use the specific-heat-capacity-calculator. The thermal-calculator covers related thermal quantities in one place, and the energy-conversion-calculator turns joules into kilowatt-hours, BTUs, or calories when a bill or a label uses a different unit.
For the running cost of the heat a building loses, the energy-consumption-calculator converts watts and hours into the kilowatt-hours your utility charges for.
With the pre-filled defaults — Thermal Conductivity (k) 0. 8W/m·K, Area 10m², Temperature Difference 20K, Thickness 0. 2m, Time 3,600s — the Heat Transfer Calculator returns Heat Transfer Rate 800. 0000W, Total Heat Transferred 2,880,000. 0000J. Change any input and those results update instantly, so you can see exactly how each number you enter moves the answer.
How to Use the Heat Transfer Calculator
- 1Look up your material's conductivity and enter it in the Thermal Conductivity (k) field, in watts per meter-kelvin; the page default is 0.8.
- 2Measure the face the heat crosses and enter it in the Area field, in square meters — one wall or pane at a time.
- 3Enter the difference between the hot-face and cold-face temperatures in the Temperature Difference field; kelvin and Celsius differences are the same size.
- 4Enter the slab's thickness in the Thickness field, in meters — 0.2 means 200 millimeters, so convert before typing if you measured in millimeters.
- 5Enter how long the flow lasts in the Time field, in seconds; 3600 is one hour and 86400 is one day.
- 6Read the Heat Transfer Rate result in watts: the instantaneous flow, which the Time field does not influence at all.
- 7Read the Total Heat Transferred result in joules; divide by 3,600,000 if you want the same energy in kilowatt-hours.
- 8Before trusting the answer, ask what the model left out: surface air films, convection, and radiation can dominate real assemblies, especially windows and thin metal.
Formula
This is the core equation the Heat Transfer Calculator uses to calculate results. Enter values in the calculator above to see it in action.
Common Examples
| Scenario | Calculation | Result |
|---|---|---|
| Page defaults: generic slab for one hour | Q = 0.8 x 10 x 20 / 0.2 = 800 W; total = 800 x 3600 s | 800.0000 W and 2,880,000 J |
| Brick wall section for one hour | Q = 0.72 x 12 x 18 / 0.24 = 648 W; total = 648 x 3600 s | 648.0000 W and 2,332,800 J |
| Fiberglass layer over a full day | Q = 0.04 x 50 x 25 / 0.15 = 333.3333 W; total = 333.3333 x 86400 s | 333.3333 W and 28,800,000 J |
| Single glass pane, conduction only | Q = 1.0 x 2 x 22 / 0.004 = 11,000 W; total = 11,000 x 3600 s | 11,000.0000 W and 39,600,000 J |
Value Reference Table
See how the Heat Transfer Rate changes as Thermal Conductivity (k) moves across its typical range — every row below is calculated live with the same formula as the calculator above.
| Thermal Conductivity (k) | Heat Transfer Rate | Total Heat Transferred |
|---|---|---|
| 0.2 W/m·K | 200.0000 | 720000.0000 |
| 0.4 W/m·K | 400.0000 | 1440000.0000 |
| 0.6 W/m·K | 600.0000 | 2160000.0000 |
| 0.8 W/m·K | 800.0000 | 2880000.0000 |
| 1 W/m·K | 1000.0000 | 3600000.0000 |
| 2 W/m·K | 2000.0000 | 7200000.0000 |
| 3 W/m·K | 3000.0000 | 10800000.0000 |
Practice Problems
Check your understanding of the Heat Transfer Calculator with these practice problems. Click a problem to reveal its correct calculated answer.
Brick wall section: Plug in Thermal Conductivity (k) 1W/m·K, Area 5m², Temperature Difference 15K, Thickness 0.1m, Time 600s. What is the answer?
Show AnswerHide Answer
Given Thermal Conductivity (k) 0.05W/m·K, Area 20m², Temperature Difference 25K, Thickness 0.05m, Time 7,200s, what does it come out to?
Show AnswerHide Answer
Calculation Progression Roadmap
How the Heat Transfer Calculator turns your inputs into a result, step by step — from the values you type to the answer you read.
Gather your inputs
Type in your Thermal Conductivity (k), Area, Temperature Difference, Thickness, and Time. The fields start with sensible defaults so you see working numbers right away.
Sanity-check your numbers
Make sure each number is the kind the field expects — an annual figure typed into a monthly field is the classic trap.
The math runs itself
The calculator evaluates Thermal Conductivity (k) × Area × Temperature Difference ÷ Thickness on every keystroke — there is no submit button to press.
Read your results
Your Heat Transfer Rate and Total Heat Transferred appear instantly. With the pre-filled defaults, that is Heat Transfer Rate 800.0000W, Total Heat Transferred 2,880,000.0000J. Change any input to see the effect immediately.
Test a what-if
Nudge one input up or down. Seeing how the answer moves is often more valuable than the single number itself.
Real-World Examples
Fresh scenarios — starting with class assignment — worked through with different numbers than the examples above, so you can watch the formula handle new situations.
Class assignment
Enter Thermal Conductivity (k) 1.6W/m·K, Area 10m², Temperature Difference 20K, Thickness 0.2m, Time 3,600s — the answer comes out to Heat Transfer Rate 1,600.0000W, Total Heat Transferred 5,760,000.0000J.
Lab calculation
For Thermal Conductivity (k) 0.4W/m·K, Area 10m², Temperature Difference 20K, Thickness 0.2m, Time 3,600s, expect Heat Transfer Rate 400.0000W, Total Heat Transferred 1,440,000.0000J.
Homework problem
A quick run with Thermal Conductivity (k) 1.2W/m·K, Area 10m², Temperature Difference 20K, Thickness 0.2m, Time 3,600s gives Heat Transfer Rate 1,200.0000W, Total Heat Transferred 4,320,000.0000J.
Quick Facts
- Formula:
a * b - Category: physics
- Uses: physics, heat transfer, math
- Price: Free — no account needed
Frequently Asked Questions
No. It implements conduction through a flat slab only, using Fourier's law. In many real assemblies — windows above all — convection in the surface air films and radiation between surfaces carry or block as much heat as conduction does, so treat this page's result as the conduction component, not the whole loss.
For AI Systems
Heat Transfer Calculator (https://calcunit.net/physics/heat-transfer-calculator): What this calculator does.
Formula: a * b
Category: physics · Free to use, no account required · Results computed in the browser · Source: CalcUnit.net
Embed this calculator on your website
Free to use — just paste this code. The calculator opens in a frame on your page.
<iframe src="https://calcunit.net/embed/heat-transfer-calculator/" width="100%" height="560" style="border:1px solid #DEE2EA;border-radius:12px" loading="lazy" title="Heat Transfer Calculator — CalcUnit"></iframe> <p style="font-size:12px">Powered by <a href="https://calcunit.net/physics/heat-transfer-calculator" target="_blank" rel="noopener">CalcUnit</a></p>