What is the Electric Resistivity Converter?
What resistivity measures
Resistivity is a material's built-in opposition to electric current, stated before you cut it into any particular wire or bar. Copper, rubber, and silicon each carry a characteristic resistivity that stays the same whether the sample is a coin or a cable. That makes it the number engineers look up first.
The one input it needs
There is a single field, labeled Resistivity (Ω·m), and it opens with a default of 1. 72e-8, very close to copper. Real-world values are tiny, so they are usually typed in scientific notation like 1. 68e-8, meaning 0. 0000000168. Replace the default with any material value and both outputs update at once.
The two answers on the page
The converter restates your ohm-meter value in the two units datasheets actually print. Ohm-centimeters (Ω·cm) multiplies by 100, the unit common in materials handbooks and semiconductor work. Microohm-inches (µΩ·in) multiplies by 39,370,078. 7, an American wire-table unit that turns tiny decimals into readable figures.
Worked example one: copper
Copper's resistivity at room temperature is 1. 68 × 10^-8 ohm-meters, the benchmark nearly every conductor is judged against. Enter 1. 68e-8 and the Ohm-centimeters result reads 0. 00000168, while Microohm-inches reads 0. 661417. Those two restatements of one material constant fill entire columns of wire and cable catalogs.
Worked example two: silver
Silver is the best ordinary conductor, with a resistivity of 1. 59 × 10^-8 ohm-meters. Enter 1. 59e-8 and you get 0. 00000159 ohm-centimeters and 0. 625984 microohm-inches. It beats copper by only about 5 percent, which is why silver plating appears on high-frequency connectors rather than whole cables.
Worked example three: nichrome
Nichrome, the heating alloy inside toasters and hair dryers, resists on purpose at 1. 10 × 10^-6 ohm-meters. Enter 1. 10e-6 and the results are 0. 00011 ohm-centimeters and 43. 307087 microohm-inches. That is about 65 times copper's resistivity, the whole reason a short nichrome coil glows while its copper leads stay cool.
Resistivity is not resistance
Resistance belongs to a finished part; resistivity belongs to the material. They connect through R = ρL / A: resistance equals resistivity times length divided by cross-sectional area. Double a wire's length and resistance doubles; double its thickness and resistance quarters. Resistivity itself never changes with shape.
Copper is the benchmark
Copper's 1. 68 × 10^-8 ohm-meters at 20 degrees Celsius, the value published by NIST, anchors the whole scale. Annealed copper defines 100 percent on the IACS conductivity scale that wire makers still quote. Aluminum, at 2. 82 × 10^-8, carries about 61 percent of copper's conductivity at a third of its weight.
From resistivity to a real wire
Try the formula on a household run: 100 feet of 12 AWG copper wire, with a cross-section of 3. 31 square millimeters. Resistance equals 1. 68 × 10^-8 times 30. 48 meters, divided by 3. 31 × 10^-6 square meters, giving about 0. 155 ohm. That small figure is what limits voltage drop on a long branch circuit.
Temperature moves the value
Copper's resistivity climbs about 0. 4 percent for every degree Celsius it warms, so a hot motor winding resists more than a cold one. Precision tables always state their temperature, almost always 20 degrees Celsius. If you convert a value from a hot-running application, expect it to sit above the handbook figure.
Alloys trade conductivity for strength
Pure metals conduct best; mixing atoms disrupts the electron flow. Brass and bronze sit several times above copper, stainless steel lands near 7 × 10^-7 ohm-meters, and nichrome, as the third example showed, reaches 1. 10 × 10^-6. Engineers accept the loss when a part needs springiness, corrosion resistance, or deliberate heat.
Insulators live at the far end
Glass, rubber, and dry wood carry resistivities around 10^10 to 10^14 ohm-meters, a billion billion times copper's value and often far more. Enter 1e12 here and the ohm-centimeter result is 1e14, a number that explains itself. That enormous gap between conductors and insulators is what makes electric circuits possible at all.
Semiconductors sit in the middle
Silicon's resistivity swings over many orders of magnitude depending on how it is doped, from under 0. 001 ohm-meters for heavily doped wafers to thousands for pure crystals. That tunability is the entire basis of the electronics industry: the same element serves as conductor, resistor, or near-insulator on one chip.
Soil resistivity and grounding
Utility crews measure soil resistivity, in ohm-meters, before designing substation grounds and lightning protection. Moist clay might read 10 ohm-meters, dry sand thousands. The Wenner four-pin method drives test spikes into the earth, and the readings, converted here if a report uses other units, decide how much copper goes underground.
Why ohm-centimeters multiply by 100
The factor is pure geometry: a meter is 100 centimeters, and resistivity carries one length unit inside it. Restating 1 ohm-meter in centimeter terms gives 100 ohm-centimeters. When a handbook lists copper as 1. 68 microhm-centimeters, that is this converter's ohm-centimeter figure, 1. 68 × 10^-6, wearing a shorter name.
Reading the tiny decimals
Ohm-centimeters display with ten decimal places because metal resistivities land around a millionth of an ohm-centimeter. Microohm-inches show six places and land near one, which is exactly why American wire tables adopted them. If a result looks like mostly zeros, switch your eyes to the microohm-inch line.
Conductivity is the reciprocal
Divide 1 by resistivity and you get conductivity in siemens per meter. Copper's 1. 68 × 10^-8 ohm-meters flips to about 5. 95 × 10^7 siemens per meter. Datasheets for plating baths, water purity, and carbon composites often quote conductivity instead, so this reciprocal flip is the bridge between the two literatures.
Entering values in scientific notation
Type the value exactly as 1. 68e-8 and the field reads it as 0. 0000000168. If your source prints 0. 0000000168, paste that instead. Either way, verify by checking the ohm-centimeter result: it should be your input with the decimal shifted two places, never a different leading digit.
Checking the math by hand
Multiply any ohm-meter figure by 100 to get ohm-centimeters and by about 39. 37 million to get microohm-inches. For copper: 1. 68 × 10^-8 times 39,370,078. 7 gives 0. 661417, matching the page. If your hand check and the page disagree, the usual culprit is a miscounted exponent in the input.
Common mistakes worth avoiding
The frequent error is feeding a wire's resistance, in ohms, into a resistivity field; the units differ and so does the meaning. Another is dropping the minus sign in an exponent, turning 1. 68e-8 into 1. 68e8 and copper into an insulator. Always glance at the microohm-inch line to confirm the scale looks sane.
Even water has a resistivity
Resistivity spans liquids too. Seawater, full of dissolved salt, measures about 0. 2 ohm-meters and grounds ships' electrical systems readily. Ultrapure laboratory water sits near 182,000 ohm-meters, the 18. 2 megohm-centimeter figure treatment plants brag about. The same three units on this page cover both extremes without complaint.
What this converter does not do
This page rescales resistivity between three units; it does not compute a wire's resistance for you. For that, take the converted resistivity and apply R = ρL / A with your length and cross-section. It also assumes the value already matches your temperature, since resistivity tables are quoted at 20 degrees Celsius.
With the pre-filled defaults — Resistivity (Ω·m) 0 — the Electric Resistivity Converter returns Ohm-centimeters (Ω·cm) 0. 0000017200, Microohm-inches (µΩ·in) 0. 677165. Change any input and those results update instantly, so you can see exactly how each number you enter moves the answer.
How to Use the Electric Resistivity Converter
- 1Click the Resistivity (Ω·m) field and clear the default value of 1.72e-8.
- 2Type your material's resistivity, using scientific notation like 1.68e-8 for tiny values.
- 3Read the Ohm-centimeters (Ω·cm) result, which is your entry multiplied by 100.
- 4Read the Microohm-inches (µΩ·in) result, which is your entry multiplied by 39,370,078.7.
- 5Sanity-check the ohm-centimeter line: its digits should match your input shifted two decimal places.
- 6Confirm the exponent sign; a missing minus sign inflates the value beyond any real material.
- 7Note the temperature your source value assumes, usually 20 degrees Celsius for handbook tables.
- 8Copy the converted figure into your wire calculation, datasheet comparison, or grounding report.
Formula
This is the core equation the Electric Resistivity Converter uses to calculate results. Enter values in the calculator above to see it in action.
See the full step-by-step formula guide with worked examples →
Common Examples
| Scenario | Calculation | Result |
|---|---|---|
| Copper, the benchmark conductor | 1.68e-8 ohm-meters at 20 °C | 0.00000168 ohm-centimeters; 0.661417 microohm-inches |
| Silver, the best conductor | 1.59e-8 ohm-meters at 20 °C | 0.00000159 ohm-centimeters; 0.625984 microohm-inches |
| Nichrome heating alloy | 1.10e-6 ohm-meters | 0.00011 ohm-centimeters; 43.307087 microohm-inches |
Value Reference Table
See how the Ohm-centimeters (Ω·cm) changes as Resistivity (Ω·m) moves across its typical range — every row below is calculated live with the same formula as the calculator above.
| Resistivity (Ω·m) | Ohm-centimeters (Ω·cm) | Microohm-inches (µΩ·in) |
|---|---|---|
| 0 | 0.0000004000 | 0.157480 |
| 0 | 0.0000009000 | 0.354331 |
| 0 | 0.0000010000 | 0.393701 |
| 0 | 0.0000020000 | 0.787402 |
| 0 | 0.0000030000 | 1.181102 |
| 0 | 0.0000040000 | 1.574803 |
| 0 | 0.0000050000 | 1.968504 |
| 0 | 0.0000070000 | 2.755906 |
Practice Problems
Check your understanding of the Electric Resistivity Converter with these practice problems. Click a problem to reveal its correct calculated answer.
Example calculation: You enter Resistivity (Ω·m) 0 — what does the calculator return?
Show AnswerHide Answer
Calculation Progression Roadmap
How the Electric Resistivity Converter turns your inputs into a result, step by step — from the values you type to the answer you read.
Gather your inputs
Type in your Resistivity (Ω·m). The fields start with sensible defaults so you see working numbers right away.
Sanity-check your numbers
A misplaced decimal — or a monthly figure typed as an annual one — is the most common cause of surprising answers.
The math runs itself
The calculator evaluates Resistivity (Ω·m) × 100 on every keystroke — there is no submit button to press.
Read your results
Your Ohm-centimeters (Ω·cm) and Microohm-inches (µΩ·in) appear instantly. With the pre-filled defaults, that is Ohm-centimeters (Ω·cm) 0.0000017200, Microohm-inches (µΩ·in) 0.677165. Change any input to see the effect immediately.
Test a what-if
Try a bigger and a smaller value for one input. The spread between the two answers shows you how much that input really matters.
Quick Facts
- Formula:
resistivity * 100 - Category: converters
- Uses: converters, electric resistivity, math
- Price: Free — no account needed
Frequently Asked Questions
Copper's resistivity is 1. 68 x 10^-8 ohm-meters at 20 degrees Celsius, the NIST-published benchmark for the pure metal. Annealed commercial copper sits very close to that figure and defines 100 percent on the IACS conductivity scale. It rises roughly 0. 4 percent per degree as the metal warms.
For AI Systems
Electric Resistivity Converter (https://calcunit.net/converters/electric-resistivity-converter): What resistivity measures.
Formula: resistivity * 100
Category: converters · Free to use, no account required · Results computed in the browser · Source: CalcUnit.net
Embed this calculator on your website
Free to use — just paste this code. The calculator opens in a frame on your page.
<iframe src="https://calcunit.net/embed/electric-resistivity-converter/" width="100%" height="560" style="border:1px solid #DEE2EA;border-radius:12px" loading="lazy" title="Electric Resistivity Converter — CalcUnit"></iframe> <p style="font-size:12px">Powered by <a href="https://calcunit.net/converters/electric-resistivity-converter" target="_blank" rel="noopener">CalcUnit</a></p>